SITEMAP   |   CAREERS   |   CONTACT US
Ultrasonic Flowmeters , Level Sensors , Water Quality Instruments
RS Hydro > Wireless Telemetry > PSTN Data Logger > Aqua TROLL 200

Aqua TROLL 200

Aqua TROLL 200  

The Aqua TROLL 200 is the first in the new range of water quality monitoring instruments from In-Situ Inc. The Aqua TROLL 200 measures conductivity, level/pressure and temperature in the harshest conditions.

The Aqua TROLL 200 is designed to combat fouling and conserve power and is built to extend deployment. Can be powered externally with 8-36 VDC or by internal batteries which are guaranteed to last for 5 years when reading every 15 minutes. The TROLL has a titanium construction, is ultra-rugged, corrossion resistant and 0.72"(18.3mm) diameter make the Aqua TROLL 200 the ideal instrument for demanding marine, surface and groundwater applications.

Building on the sucessful Level TROLL platform, the Aqua TROLL 200 is SCADA and telemetry ready. Standard outputs include Modbus/RS485, SDI-12 and 4-20 mA.

With a high accuracy pressure sensor, the Aqua TROLL 200 also allows superior water level accuracyin estuary and coastal environments where salinity values vary due to mixing, rainfall or tides by dynamically compensating level readings for changes in water density due to changes in salinity.

Choice of either gauged or absolute models with ranges up to 500psi. All models feature a 4MB memory which can store up to 380,000 data points. Standard logging modes include linear, linear average and event testing with logging rates as fast as 1/sec. Easy to install using an In-Situ Rugged cable. Data aquisition is made easy using Win-Situ software. Rugged Reader is also available for quick instrument set-up and downloading in the field.

Applications

The Aqua TROLL 200 applications include:

  • Wetlands Applications
  • Tide Gauge Monitoring
  • Pumping tests
  • Saltwater Intrusion Projects
  • Ground Water Monitoring
  • Discharge Monitoring
  • Surface Water Monitoring
  • Research, studies
  • Aquifer Storage and Recovery
  • Landslide Prediction

Specifications

Power  
Internal Battery  
External Power  
Typical Battery Life  
   
Logging  
Memory 4MB, 380,000 data points**
Log Types Linear, Linear Average*** and Event***
Fastest Reading*Rate  
Linear 1 per minute
Linear Average*** 1 per second
Event*** 1 per second
Fastest Logging Rate  
Linear 1 per minute
Linear Average*** 1 per minute
Event*** 1 per second
Maximum Number of Logs 50
*1 reading = time and date plus all available parameters polled or logged from device.
**1 data point - time and date plus one parameter logged.
***External power supply or battery pack required when using event testing, recommended when using linear average testing.
Temperature  
Material Titanium
Range -20ºC to 65ºC(-0ºF to 149ºF)
Unit of measure Celcius or Fahrenheit
Accuracy +/-0.1ºC
Resolution 0.01ºC
   
Conductivity  
Sensor Type Balanced 4-electrode cell
Sensor Material PVC, Titanium
Range 5µS/cm-100,000µS/cm
Accuracy +/-0.5% of reading plus 1µS/cm from 5µS/cm to 80,000µS/cm
  +/-1.0% of reading from 80,000 µS/cm to 100,000µS/cm
Resolution 0.1µS/cm
Parameters Supported * Units Range
Actual Conductvity µS, mS 5µS/cm - 100,000µS/cm
Specific Conductivity** µS, mS 5µS/cm - 100,000µS/cm
Salinity*** PSU 0-42 PSU
TDS ppm,ppt 0-82ppt
Resistivity Ohms-cm 10 Ohms-cm - 200,000 Ohms-cm
Density(Water) gm/cm³ 0.98-1.14 gm/cm ³
*Parameters derived at 25 ºC and Actual Conductivity range of 5µS/cm - 100,000 µS/cm with a +/-0.05% plus 1µS/cm accuracy;
**Dervived from Standard methods 2510B
***Defined by the Practical Salinity Scale 1978 Standard Methods 2520B.
****Real time Level compensation for Density of water.
   
Pressure/Level*  
Sensor Type Silicon Strain Gauge
Material Titanium
Range, Non Vented 30,100,300,500 psia
  35.8, 197.3, 658.7, 658.7, 1120 ft
  10.9, 60.1, 200.7, 341.3m
Range, Vented 5, 15, 30, 100, 300, 500 psig
  11.5, 35, 69, 231, 692, 1153 ft
  33.5, 11, 21, 70, 210, 351m
Unit of Measure PSI, KPa, mm, cm, m, in, ft, Bar, mBar, mmHg
Accuracy**  
@15ºC +/-0.05% Full Scale (FS)
0ºC to 50ºC +/-0.1%
-20ºC to -1ºC and 51ºC to 80ºC +/-0.25% FS
Resolution +/-0.005% FS or better
Max. Pressure 2X Range
Burst Pressure 3X Range
* Real time Level compensation for density
**Accuracy with 4-20 mA output option: +/- 0.25% FS

Download Product Specification Download PDF
Download User Manual Download PDF

 

Options
 
Quote
Vented
Range
Required
Quantity

        

View Quote Cart
Live Chat
Data Portal
RSS Feed
 Search