The Transmag 2 transmitters are designed for heavy-duty applications such as
pulp & paper stock over 3%; heavy mining slurries and mining slurries with
magnetic particles. This is a truly robsut option compatible with 911
flowmeters.
It has high signal-to-noise ratio by transient phenomenon - 10 times higher
than the pulse DC version, 2 times higher than the pulse AC system in the market.
Measurement of magnetically conductive media is possible by measurement of
the field strength in the transducer. Solids up to 85% and two phase materials
are not a problem for this technology. It comes complete with self-cleaning
electrodes, self-diagnostics for error detection and a mulit-lingual display.
| Transmitter |
TRANSMAG 2 |
| Measuring principle |
Pulsed alternating field |
| Enclosure |
IP67 / NEMA 4X |
| Max Measuring Error |
0.5% of rate |
| Display |
2 lines alpha numeric LCD with back light |
| Inputs & outputs |
1 current, 1 digital, 1 relay (or 1 digital input) output |
| Communication |
HART, Profibus PA |
| Power Supply |
100-230 VAC |
|