Solinst Barologger Edge Barometric Datalogger

  • Compatible with all Levelogger Versions IN STOCK. Next Day Delivery
  • Accuracy +/- 0.05 kPa (air only)
  • Range of Sampling Modes Linear, Event & User-Selectable Schedule with Repeat Mode, Future Start, Future Stop, Real-Time View
  • Corrosion Resistant Titanium based PVD coating on body and a corrosion resistant Hastelloy sensor
Product Options
110179

Overview

Absolute pressure (water pressure + atmospheric pressure) is measured by the Levelogger Edge and is expressed in meters, centimeters, feet, psi, kPa or mBar. To obtain changes in water level accurately, atmospheric pressure fluctuations need to be compensated for using a Barologger Edge which avoids time lag in the compensation.

The Barologger is set above high water level in one location on site. A single Barologger can be used to compensate for atmospheric pressure for all Leveloggers in a 30 km (20 mile) radius and/or with every 300 m (1000 ft) change in elevation.

Compensated data files are automatically produced by the Levelogger Software Data Compensation Wizard using the synchronized data files from the Barologger and Leveloggers on site.

Pressure algorithms, based on air rather than water pressure, are used by the Barologger Edge providing superior accuracy. The recorded barometric information is also useful to determine barometric lag and/or barometric efficiency of the monitored aquifer.

Atmospheric pressure is recorded by the Barologger Edge in psi, kPa or mBar. When compensating data from the Levelogger Edge, Gold or Junior, Levelogger Software Version 4 can recognize the type of Levelogger and compensate using the same units found in the data file (Levelogger Gold and Junior measure in centimeters, meters or feet). This makes the Barologger Edge backwards compatible.

Manufactured by: Solinst
Model: Solinst Barologger Edge Barometric Datalogger

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance

Applications

Pump and slug tests
Reservoir and stormwater runoff management
Watershed and drainage basin monitoring
Stream gauging, lake and wetland monitoring
Tank level measurement
Monitoring water levels in wells and surface water

Specification

Level Sensor: Piezoresistive Silicon with
Hastelloy Sensor
Accuracy (Typical) ± 0.05 kPa
Resolution 24 Bit Resolution
Normalization Automatic Temp Compensation
Temperature Sensor: Platinum Resistance Temperature
Detector (RTD)
Temp. Sensor Accuracy ± 0.05°C
Temp. Sensor Resolution 0.003°C
Temp. Compensation
Range
-10°C to 50°C
Battery life 10 years (based on 1 reading/
minute)
Clock Accuracy ± 1 minute/year (-20°C to 80°C)
Operating Temperature - 20°C to 80°C
Maximum # Readings 40,000 (up to 120,000 using data
compression)
Memory FRAM, Continuous or Slate mode
Communication Speed 9600 bps, 38,400 bps with USB optical
reader
Communication Interface Optical Infra-red: USB, RS-232,
SDI-12
Size 7/8" x 6.25"
(22 mm x 159 mm)
Weight 129 grams (4.5 oz.)
Corrosion Resistance Titanium based PVD coated body
and superior corrosion resistant
Hastelloy sensor
Other Wetted Materials Delrin®, Viton®, 316L Stainless Steel
Sampling Modes Linear, Event & User-Selectable
Schedule with Repeat Mode,
Future Start, Future Stop,
Real-Time View
Measurement Rates 0.125 second to 99 hours

Downloads

Accessories

FAQ's

The free app is available on both Apple® and Android™ smart devices.
Apple devices must be running iOS 11 or later on the following compatible devices:

  • iPhone
  • iPad
  • iPad mini
  • iPod touch.

Android devices must be running version 5.0 or higher. Solinst does not guarantee compatibility on all devices running 5.0, but testing confirms the following can be used:

  • Phone: Samsung Galaxy S4 - Model SGH-1337M
  • Phone: Samsung Galaxy S5 - Model SM-G900W8
  • Tablet: Samsung Tab 4 (10.1”) - Model SM-T530NU

As the Levelogger App Interface will not connect directly to the top of a Solinst datalogger, it is necessary to have connection accessories. With the Levelogger or Rainlogger, one of the following accessories is required:

  • Direct Read Cable, clients use this option to suspend dataloggers in the field when they wish to communicate downhole.
  • When working with Leveloggers that are suspended from wireline, or cord, the units must be removed from the well and connected to either a Direct Read Cable (as above) or an Optical Adaptor.
  • For the LevelVent, just connect to the unit via the Vented Cable and LevelVent Wellhead that all units are suspended from in the field – no other connection accessories are required.
  • The AquaVent communication connection is made from the App Interface to the AquaVent Wellhead using an App Connector Cable that is ordered separately.
The Levelogger App Interface is portable hardware that connects to the top of your Levelogger via a Direct Read Cable/Adaptor, to a LevelVent Wellhead, or to an AquaVent Wellhead cable. Bluetooth wireless technology allows communication between the Levelogger App Interface and the smart device with the app installed. It allows viewing/downloading of data, and programming of Solinst dataloggers, as well as many other features.
Solinst offers a wide range of dataloggers that can be used with the Leveloggger App Interface. They include the complete, current Levelogger Edge range of units (Edge, Junior Edge, LTC Edge, Rainlogger Edge), previous Gold Leveloggers/Barologgers, and the latest vented datalogger editions, the AquaVent and LevelVent.
  • Program and start dataloggers in the field.
  • Simplify data management in the field by transporting and using less equipment.
  • View real-time readings.
  • Download and e-mail logged data files.
  • Calibrate LTC Leveloggers (NEW).
  • Run the diagnostic utility (NEW) – used for troubleshooting

Leveloggers. Provides detailed information on the datalogger,
and includes options for running a self-test, doing a memory
dump and creating/emailing reports.

The most recent version of the Android App available is 1.2.5 but that is only available for download if your Android device has Android version 8 (oreo) or above. That means, any device running older Android versions can not download the most recent App-This is a restriction that Google has set.
Restart the Barologgers in psi and download the Barologger file with an Optical Reader/ PC Interface Cable with the PC software.