Panametrics AT868

The AT868 flow meter combines state of the art ultrasonic flow measurement capability with a low-cost transmitter package that can be installed right at the process measurement point. It's designed specifically for water and wastewater applications in full pipes. The AT868 ultrasonic flowmeter is offered with wetted or dry clamp-on transducers for convenience. Wetted transducers offer accuracies better than 1%. The AT868 flowmeter has no moving parts and requires minimal maintenance. An onboard microprocessor used patented Correlation Transit TimeTM technology for long-term drift-free operation. Automatic adjustment to changing fluid properties and dynamically configured operating software simplify programming.

The AT868 can also be used in conjunction with Heat Meters to enable energy calculations.

Applications

  • Potable water
  • Wastewater
  • Sewage
  • Discharge water
  • Treated water
  • Cooling and heating water
  • Other liquids
Flow Range 0.03-12.2m/sec
Accuracy ?1 to 2% of reading
Repeatability 0.1-3% with unchanged transducer positions
Pipe Size 13-7600mm

Operating Temperature

Transducers

-40?C to +100?C (Wetted Option: -40?C to +230?C

Transmitter

-10?C to 55?C
Datalogging n/a
Output One 4-20mA and one pulse per flow channel
Power Built-in battery with external 12v input, 8 hours operation
Dimensions 238 x 138 x 38 mm
Weight (Control Unit) 3lbs (1.36kg)
Channels Option to measure two flows with single transmitter.