HOBO MX1102A Carbon Dioxide - Temp - RH Data Logger

Product Options

Overview

Onset's HOBO MX1102 CO2 logger makes it more convenient than ever to measure and record CO2 in buildings and other non-condensing environments. It measures CO2 from 0–5,000 parts per million (ppm) – and our free HOBOconnect app lets you access data right from your mobile phone or tablet within a 100-foot range of the logger.

The MX1102 also features a USB port so it can be used with a computer running HOBOware graphing & analysis software.

Add the MX Gateway for remote access to your data in Onset's cloud-based HOBOlink software.

Manufactured by: Onset
Model: HOBO MX1102A Carbon Dioxide - Temp - RH Data Logger

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance

Applications

Carbon DIoxide
Dew point
Relative humidity
Temperature

Specification

Temperature Sensor
Range 0° to 50°C (32° to 122°F)
Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Resolution 0.024°C at 25°C (0.04°F at 77°F)
Drift <0.1°C (0.18°F) per year
RH Sensor
Range 1% to 90% RH (non-condensing)
Accuracy ±2% from 20% to 80% typical to a maximum of ±4.5% including hysteresis at 25°C (77°F); below 20% and above 80% ±6% typical
Resolution 0.01%
Drift <1% per year typical
CO2 Sensor
Range 0 to 5,000 ppm
Accuracy ±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH non-condensing and 1,013 mbar
Warm-up Time 15 seconds
Calibration Auto or manual to 400 ppm
Non-linearity <1% of FS
Pressure Dependence 0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range 950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range -305 to 5,486 m (-1,000 to 18,000 ft)
Sensing Method Non-dispersive infrared (NDIR) absorption
Response Time
Temperature 12 minutes to 90% in airflow of 1 m/s (2.2 mph)
RH 1 minute to 90% in airflow of 1 m/s (2.2 mph)
CO2 1 minute to 90% in airflow of 1 m/s (2.2 mph)
Logger
Radio Power 1 mW (0 dBm)
Transmission Range Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard Bluetooth Smart (Bluetooth Low Energy, Bluetooth 4.0)
Logger Operating Range 0° to 50°C (32° to 122°F); 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
Logging Modes Fixed interval (normal, statistics) or burst
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, date & time, or after a set logging period
Time Accuracy ± 1 minute per month at 25°C (77°F)
Power Source 4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts) 
Battery Life 6 months, typical with logging and sampling intervals of 5 minutes or slower; 6 months or less with logging and sampling intervals faster than 5 minutes while logging CO2. Entering burst logging mode will impact battery life. With app use, battery life can be reduced by remaining connected, excessive readouts, audible alarms, and paging. Visual/audible alarms and other events can have a marginal impact on battery life.
Memory 128 KB (84,650 measurements, maximum)
Download Type USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time 20 seconds via USB; approximately 60 seconds via Bluetooth Smart, may take longer the further the device is from the logger
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size 7.62 x 12.95 x 4.78 cm (3.0 x 5.1 x 1.88 inches)
Weight 267.4 g (9.43 oz)
Environmental Rating IP50
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).

Downloads