ISCO 720 Submerged Probe Flow Module

  • Built-in flow conversions for most applications Manning formula, flumes and weirs, data points, or equations for special situations
  • Flow & Level Readings viewable and recorded on Autosampler live
  • Trigger ISCO 6712 based on flow or level.
  • Ideal for Stormwater monitoring & Combined sewer overflow studies
Product Options

Overview

The ISCO 720's flow probe is mounted at the bottom of a channel, and measures the level of a flow stream using a differential pressure transducer. Built-in conversions in the 6712 sampler then convert the level measurement into flow rate. The probe is suitable for small channels and has a venting system which compensates for changes in atmospheric pressure automatically to maintain accuracy. The 720 can provide accurate measurement at sites where steam, wind, foam, air temperature fluctuations or turbulence exist, and it accurately senses pressure, even when covered in sand or silt.

If your application uses a flume, most have a recess in which the 720's probe can be attached. The probe can easily be installed in round pipes, open channels and manhole inverts using Isco mounting rings. To avoid costly and potentially hazardous manhole entries the Isco Street Level Installation tool can also be used.

Standard Features of the 720 Module

  • Built-in flow conversions for most applications including Manning formula, flumes and weirs, data points, or equations for special situations
  • Accuracy of submerged probe not affected by steam, wind, foam, turbulence or changes in air temperature.
  • All flow data stored in the sampler is available for retrieval and can be used in reporting, graphing and analysis using Flowlink software.
  • LCD display can be used to view current flow and level values.

Manufactured by: Teledyne ISCO
Model: ISCO 720 Submerged Probe Flow Module

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance

Applications

Flow measurement where wind, foam, steam or turbulence may otherwise affect flow measurement
Collecting flow proportional samples
Trigger 6712 sampler based on flow or level
Monitoring stormwater
Treatment capacity analysis
Long-term river/stream gauging
Combined sewer overflow studies

Specification

720 Module
Size (HxWxD) 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm)
Weight 1.1 lbs (0.5 kg)
Material Polystyrene
Enclosure NEMA 4X, 6 IP67
Power 9 to 14V DC (provided by 6700 Series Sampler)
Program Memory Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC
Operating Temperature 32° to 120°F (0° to 49°C)
Storage Temperature 0° to 140°F (-18° to 60°C)
Submerged Probe
Dimensions 9.5 x 0.875 in (24.1 x 2.2 cm)
Level Measurement Method Submerged pressure transducer mounted in the flow stream
Transducer Type Differential linear integrated circuit pressure transducer
Operating Temperature 32° to 160°F (0° to 71°C)
Compensated Temperature 32° to 100°F (0° to 38°C)
Submerged Probe (continued)
Materials Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC); PVC Cable
Level Measurement Range 0.1 to 10 ft (0.03 to 3.05 m)
Maximum Allowable Level 20 ft (6.1 m)
Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range)
0.1 to 5.0 ft (0.03 to 1.52 m) ±0.01 ft (±0.003 m)
0.1 to 7.0 ft (0.03 to 2.13 m) ±0.03 ft (±0.009 m)
0.1 to 10 ft (0.03 to 3.05 m) ±0.10 ft (±0.03 m)
Temperature Coefficient (Max error per degree of temperature change over compensated range)
0.1 to 4.0 ft (0.03 to1.22m) ±0.005ft/°F (±0.0027m/°C)
4.0 to 10 ft (1.22 to 3.05m) ±0.007ft/°F (±0.0038m/°C)

Downloads