The ISCO 720's flow probe is mounted at the bottom of a channel, and measures the level of a flow stream using a differential pressure transducer. Built-in conversions in the 6712 sampler then convert the level measurement into flow rate. The probe is suitable for small channels and has a venting system which compensates for changes in atmospheric pressure automatically to maintain accuracy. The 720 can provide accurate measurement at sites where steam, wind, foam, air temperature fluctuations or turbulence exist, and it accurately senses pressure, even when covered in sand or silt.
If your application uses a flume, most have a recess in which the 720's probe can be attached. The probe can easily be installed in round pipes, open channels and manhole inverts using Isco mounting rings. To avoid costly and potentially hazardous manhole entries the Isco Street Level Installation tool can also be used.
Manufactured by: Teledyne ISCO
Model: ISCO 720 Submerged Probe Flow Module
Flow measurement where wind, foam, steam or turbulence may otherwise affect flow measurement
Collecting flow proportional samples
Trigger 6712 sampler based on flow or level
Monitoring stormwater
Treatment capacity analysis
Long-term river/stream gauging
Combined sewer overflow studies
720 Module | |
Size (HxWxD) | 4.9 x 5.7 x 2.0 in (12.4 x 14.5 x 5.1 cm) |
Weight | 1.1 lbs (0.5 kg) |
Material | Polystyrene |
Enclosure | NEMA 4X, 6 IP67 |
Power | 9 to 14V DC (provided by 6700 Series Sampler) |
Program Memory | Non-volatile, programmable flash; can be updated via interrogator port on 6700 Series Sampler using a PC |
Operating Temperature | 32° to 120°F (0° to 49°C) |
Storage Temperature | 0° to 140°F (-18° to 60°C) |
Submerged Probe | |
Dimensions | 9.5 x 0.875 in (24.1 x 2.2 cm) |
Level Measurement Method | Submerged pressure transducer mounted in the flow stream |
Transducer Type | Differential linear integrated circuit pressure transducer |
Operating Temperature | 32° to 160°F (0° to 71°C) |
Compensated Temperature | 32° to 100°F (0° to 38°C) |
Submerged Probe (continued) | |
Materials | Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC); PVC Cable |
Level Measurement Range | 0.1 to 10 ft (0.03 to 3.05 m) |
Maximum Allowable Level | 20 ft (6.1 m) |
Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range) | |
0.1 to 5.0 ft (0.03 to 1.52 m) | ±0.01 ft (±0.003 m) |
0.1 to 7.0 ft (0.03 to 2.13 m) | ±0.03 ft (±0.009 m) |
0.1 to 10 ft (0.03 to 3.05 m) | ±0.10 ft (±0.03 m) |
Temperature Coefficient (Max error per degree of temperature change over compensated range) | |
0.1 to 4.0 ft (0.03 to1.22m) | ±0.005ft/°F (±0.0027m/°C) |
4.0 to 10 ft (1.22 to 3.05m) | ±0.007ft/°F (±0.0038m/°C) |