The A753 GSM / GPRS Telemetry datalogger is a comprehensive datalogger with in-built power provision for attached sensors. is a complete overhaul of its successful predecessor the A733 GPRS and can be used for a huge variety of applications.
Water quality sondes such as the Manta2 have digital SDI-12 interfaces to increase compatibiliy and accuracy. A753 allows the operation of up to 40 SDI-12 or modbus (requires additional low cost option adapter), 12 0-2,5V inputs with 16-bit resolution for accurate analog sensors along with 4 digital pulse inputs and 4 digital outputs for switching processes on/off such as valves or pumps.
The A753 telemetry datalogger is without doubt the most cost-effective and comprehensive datalogger of its kind. Whether you wish to connect to water meters, turbidity sensors, water quality sondes, weather stations, groundwater sensors, 30 level sensors, turn pumps on/off, the A753 telemetry datalogger is without doubt the only instrument that can do the job.
Manufactured by: Adcon Telemetry
Model: A753 GSM GPRS Telemetry Data Logger
All round RTU, extremely compact, extremely rugged, extremely low-power
WMO compliant
Flood warning, dam monitoring
Agriculture & public water supply
Science, research & development, and much more
SDI-12 water quality station
ModBus Sensors
Dimensions | 160 x 60 x 80 mm |
Weight | 1.200gr. |
Ingress Protection Class | IP-67 |
Temperature Range | -30°C to +65°C |
Case | Powder-Coated Aluminium |
Scerw Connections | Flange sockets of nickel-plated brass, stainless cover screws |
Connectors (all connectors IP67 if properly mated or capped) | 4x Binder M9 7-pin to sensors 1x Binder M9 5-pin to solar cell / power supply 1x TNC Antenna connector |
Power Supply | 6,2 V NiMH battery 3.100 mAh + solar cell / mains adapter |
I/O-Ports | 12x analog in ( 0 ... 1/2,5 VDC ; including 3x 0 ... 150mV ) 4x pulse counter 4x digital in/out ( 0 ... 3V TTL) 40x SDI-12 values |
Sensor excitation | - unregulated batt. 5,6V ... 7,2V - regulated from 3,3V ... 5,5V |
Sampling Interval | User specific (from 10sec. to 12h) |
Measuring Method | Synchronous & asynchronous |
Internal Memory | 2MB for up to 500.000 values |
Resolution | 16-Bit @ 0 ... 2,5 V ; 2x 50Hz and 2x 500Hz pulse counter |
Wind Port C | Measures wind 4x per second and calculates 3-sec. average |
Rain Port D | Time stamps every pulse |
Digital Events | Records and time stamps every status change on a digital input |
Operating time (without charging of internal battery) |
In standard mode up to 21 days, in power-save mode up to 6 months; depends on slot-time, transmission rate, and sensors |
Frequency Range | 850 / 900 / 1800 / 1900 MHz |
Rx Sensitivity | -106 dBm |
Tx Output Power | Max. 2 W (depends on frequency) |
Transmission Distance | Max. 36km as per GSM standard |
Expansion (optional) | Internal Modbus IF via RS 485 |
Antenna | Omnidirectional quad-band, 2dBi |
Type approvals | R&TTE, FCC Part 15, ACMA Australia, Industry Canada, etc. |