5-Star Plus Multimeter

It has over 2,000 hours of battery life. It offers a full complement of GLP related features including a CFR Part 11 software option.

Optional 1 to 5 point calibration for pH, direct ion and conductivity measurement ensures a high level of accuracy. It also has automatic salinity correction for DO when measuring conductivity simultaneously.?

The unit has a bright LCD display with ready indication and balanced comfortable handling. It has the ability to turn off the data log and to print or view the last 10 calibrations. Up to 500 data points can be stored.

The measurement process can be simplified with the SMART STABILITYTM?and SMART AVERAGINGTM functions.

Calibration and measurement accuracy is increased with the improved stability algorithm. The slope of segment, average slope and temperature of solution and membrane are printed with the measurement.

Addition features include:

  • Ability to turn off BOD stirrer
  • Solution and membrane temperature printed with measurement
  • IP67 waterproof rating (may be immersed for up to one hour with no water incursion)
  • Self diagnostic tests
  • Auto-read/hold function
  • Automatic barometric pressure compensation
5-Star Portable Multimeter Specification
pH :
Readout Range / Resolution : -2.000 to 19.999 / 0.1,0.01,0.001
Relative Accuracy : ? 0.002
SMART STABILITY? and SMART AVERAGING? : Resolution dependent / automatic
AUTO-CAL? and/or Manual Calibration : 1 to 5 points; US/NIST, DIN, and custom buffers recognized
ISE :
Range / Resolution : 0 to 19900 / 1,2, or 3 significant digits
Relative Accuracy : ? 0.2 mV or 0.05%, whichever is greater
SMART STABILITY? and SMART AVERAGING? : Resolution dependent / automatic
Units : M, mg/L, %, ppb, or no units
# ISE Cal points : 1 to 5
Special ISE Calibration Features : Linear point to point, selectable auto-blank non-linear, low concentration range
mV :
Range ? mV / RmV : ? 1999.9
ORP : EH autocalibration to standard hydrogen electrode
Resolution : 0.1
Relative Accuracy : ? 0.2 mV or 0.05%, whichever is greater
Conductivity :
Range : 0.000 to 3000 mS/cm, auto resolution with cell constant dependence
Resolution : 4 significant digits down to 0.001 ?S/cm, cell constant dependent
Relative Accuracy : 0.5% ? 1 digit or 0.01 ?S/cm, whichever is greater
Cell Constant : 0.001 to 199.9
Cell Compatibility : 2 Cell, 4 Cell, Planar Cell
SMART STABILITY? and SMART AVERAGING? : Resolution dependent / automatic
DirectCal? / AUTO-CAL? : 1 to 5 points / 1 to 3 points
RESISTIVITY :
Range / Resolution : 0.0001 to 100 Megohm / Auto resolution
Relative Accuracy : 0.5 % ? 1 digit
SALINITY :
Range / Resolution : 0.1 to 80.0 ppt NaCl equivalent, 0.1 to 42ppt practical salinity / 0.1
Relative Accuracy : ? 0.1 ? 1 digit
TDS :
Range / Resolution : 0 to 19999 / 1 mg/L
Adjustable TDS Factor : 0.00 to 10.00
Range / Resolution Concentration : 0.00 to 90.0 mg/L / 0.0/0.00
Range / Resolution % Saturation : 0.0 to 600% / 0/0.0
Relative Accuracy Concentration / % Saturation : ? 0.5% ?1 digit
SMART STABILITY? and SMART AVERAGING? : Resolution dependent / automatic
Auto Calibration or Manual Input : Water Saturated Air and Air Saturated Water, Winkler
Calibration to Winkler Titration for BOD : Available as needed
Salinity Factor : 0 to 45 ppt
Barometric Pressure Range : 450 to 850 mm Hg
Probe Type : Polarographic
Temperature :
Range / Resolution : -5 to 105 ?C / 0.1 up to 99.9 ?C , 1.0 over 99.9 ?C
Relative Accuracy : ? 0.1?C
Temperature Compensation : DO (auto); Cond (nLF, linear 0.0 to 10.0% / ?C); pH (auto/manual)
Display : Custom backlit LCD, for easy viewing
INPUTS / OUTPUTS :
Sensor Inputs : Conductivity-miniDIN - Locking; DO-miniDIN - Locking; ATC-miniDIN-Locking; pH/ISE - BNC; (all waterproof)
Communications : Waterproof bi-directional RS232 - Stereo jack, optional USB interface Cable
SPECIAL GLP SOFTWARE FEATURES :
# Of Data Logging Points : 500 points by time, stability or manual read with time/date stamp
Calibration Log : Last 10 Calibrations
User Method Storage : 10 Saved
Advanced Self-test and Diagnostics : YES
GLP Electrode Verification : YES
Password Protection : YES
Internet Software Updates / Downloadable Methods : YES
21 CFR Part 11 Software Package : YES
Power : 4 x AA batteries, powerless date protection
Regulatory and Safety : CE, CSA, UL, T?V, FCC Class A limits
ENVIRONMENTAL OPERATING CONDITIONS :
Ambient Operating Temperature : 5 to 45?C
Relative Humidity : 5 to 85% Non-Condensing
Warranty : 36 months (from date of purchase)