The 3710 Automatic Sampler is simple to operate and has high volume capacity for single - bottle sampling. Composite samples can be collected either at flow or time based intervals.
Auotmatic samples can be collected in either a 2.5 gallon glass or polyethylene bottle, or a 4 gallon polyethylene bottle. Up to 24 sampling stop and resume times can be preset for unattended, automatic sampling.
Set up and programming of the automatic sampler is easily done. All the user has to do is choose the options needed from the selections displayed on the two-line, backlit LCD.
The ISCO 3710 automatic sampler has a thermal resistance of R-11 which allows maximum effectiveness for cooling samples. The base of the sampler is insulated by one inch thick foam, keeping the unit more rigid and less affected by ambient temperatures.
Standard Features
Applications
Options and Accessories
Manufactured by: Teledyne ISCO
Model: ISCO 3710 Portable Composite Sampler
Watewater effluent
CSO monitoring
Permit compliance
Pretreatment compliance
Sampler | |
Height | 25 in (64 cm) |
Diameter | 19 in (50.5 cm) |
Weight (dry) | 37 lbs (16.8 kg) |
Cooling capacityy (w/20 lbs of ice and 4-gal container full of 65° F water) | |
After 24 hrs After 48 hrs |
32° F (18° C) below ambient 25 °F (14 °C) below ambient |
(standard thermal resistance factor of R-11) |
|
Power required | 12 VDC |
Pump | |
Intake purge | Adjustable air purge before and after each sample |
Suction tubing | |
Allowable length | 3 to 99 ft (1 to 30 m) |
Material | Vinyl or PTFE/FEP lined |
Inside dimension | 3/8 or 1/4 in (1.0 or 0.6 cm) |
Maximum sample lift | 26 ft (7.9 m) |
Typical line transport velocity | @ 3 ft (0.9 m) head height: 2.5 ft/s (0.76 m/s) @10 ft (3.1 m) head height: 2.5 ft/s (0.76 m/s) @15 ft (4.6 m) head height: 1.9 ft/s (0.58 m/s) |
Typical repeatability | ± 10 ml |
Pump tubing | |
Recommended life | 500,000 pump counts (Note: A tubing life warning indicator is provided) |
Liquid presence detector | Non-wetted, nonconductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller | |
Dimensions (HxWxD) | 6.75 x 13.0 x 10.0 in (17.0 x 33.0 x 25.0 cm) |
Weight (dry) | 11.0 lbs (5.9 kg) |
Operating temperature | 32° to 120°F (0° to 49° C) |
Enclosure rating | NEMA 4X, 6 (IP67) |
Program memory | Non-volatile ROM |
Flow meter signal requirements | 5 to 15 VDC pulse or 25 ms isolated contact closure |
Interface port | 8-pin connector; data output at 2400 baud in ASCII RS-232 format with handshake |
Real time clock accuracy | 1 minute per month, typical |
Software | |
Sample frequency selection | : 1 minute to 99 hours and 59 minutes, in oneminute increments. Non-uniform times in minutes or clock times: 1 to 9,999 flow pulses |
Sampling modes | |
Sample pacing | Uniform time, non-uniform time, flow. Note: Flow pacing is controlled by external flow pulses. |
Multiplexing | Samples per bottle: 1 to 50 with 100 ml bottles 1 to 17 with 350 ml bottles Bottles per sample: 1 to 24, multiple bottle compositing |
Programmable sample volumes | 10 to 9,999 ml, in 1 ml increments |
Sample retries | If no sample is detected, up to 3 attempts (user selectable) |
Rinse cycles | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program storage | 3 sampling programs |
Sampling stop/resume | Up to 24 real time/date stop/resume commands |
Controller diagnostics | Tests for RAM, ROM, pump display, and distributor |