The 6712C is a compact portable sampler which can fit into 18" and offset manholes. Transporting the unit is made safe and easy with the large comfortable handles. The NEMA 4X, 6 (IP67) enclosure is submersible, watertight, and dust-tight. The Plug-in 700 Series Modules and the SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system.
The advanced 6712 Controller allows the user to choose from a selection of programming modes to ensure the most suitable program for the application.
Programming is made fast and simple.
Standard Programming mode allows the user is walked through the sampling sequence step by step, allowing the user to the correct parameters specific to the application. The Extended Programming Mode lets the user enter more complex programs including smart sampling event notification, triggered on any combination of up to 16 inputs.
Manufactured by: Teledyne ISCO
Model: ISCO 6712C Compact Portable Waste Water Sampler
Wastewater effluent
Stormwater monitoring
CSO monitoring
Permit compliance
Pretreatment compliance
6712C Compact Portable Sampler | |
Size (Diam x Ht) | 17.7 x 27.6 inches (45.7 x 70.1 cm) |
Weight | Dry, Less Battery - 31 lbs (14 kg) |
Material | Plastic with UV-resistant gel coat |
Power Requirements | 12 VDC |
Pump | |
Intake Purge | Adjustable air purge before and after each sample. |
Tubing Life Indicator | Provides a warning to change pump tubing. |
Intake Suction Tubing | Vinyl or PTFE/FEP 3/8 inch (1 cm) ID; 3 to 99 feet (1 to 30 m) Length |
Pump Tubing Life | Typically 1,000,000 pump counts |
Maximum Lift | 28 feet (8.5 m) |
Repeatability | Typical ±5 ml or ±5% of the average volume in a set |
Typical Line Velocity @ Head Height | 3.0 ft./s @ 3 ft; 2.9 ft./s @ 10 ft; 2.7 ft./s @ 15 ft. (0.91 m/s @ 0.9 m; 0.87 m/s @ 3.1 m; 0.83 m/s @ 4.6 m) |
Liquid Presence Detector | Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. |
Controller | |
Weight | 13 lbs. (5.9 kg) |
Size (H x W x D) | 10.3 x 12.5 x 10 inches (26 x 31.7 x 25.4 cm) |
Operational Temperature | 32° to 120°F (0° to 49°C) |
Enclosure Rating | NEMA 4X, 6 IP67 |
Program Memory | Non-volatile ROM |
Flow Meter Signal Input | 5 to 15 volt DC pulse or 25 millisecond isolated contact closure. |
Number of Composite Samples | Programmable from 1 to 999 samples. |
Clock Accuracy | 1 minute per month, typical, for real time clock |
Software | |
Sample Frequency | 1 minute to 99 hours 59 minutes, in 1 minute increments. Non-uniform times in minutes or clock times 1 to 9,999 flow pulses |
Sampling Modes | Uniform time, non-uniform time, flow, event. (Flow mode is controlled by external flow meter pulses.) |
Programmable Sample Volumes | 10 to 9,990 ml in 1 ml increments |
Sample Retries | If no sample is detected, up to 3 attempts; user selectable |
Rinse Cycles | Automatic rinsing of suction line up to 3 rinses for each sample collection |
Program Storage | 5 sampling programs |
Sampling Stop/Resume | Up to 24 real time/date sample stop/resume commands |
Controller Diagnostics | Tests for RAM, ROM, pump display, and distributor |