The Isco 4220 Flow Logger measures depth using a differential pressure transducer. The venting system compensates for atmospheric pressure changes automatically and can measure pressure accurately even when covered with sand or silt. The 4220 can provide accurate measurement at sites where steam, wind, foam, air temperature fluctuations, or turbulence exists.
Most flumes are available with an integral recess that can be used for mounting the submerged probe. Installation of the probe in manhole inverts and round pipes is made easy with Isco mounting rings. The Isco Street Level Installation Tool can be used for installing the 4220 from ground level, elimination the need for costly and potentially hazardous manhole entry.
Manufactured by: Teledyne ISCO
Model: ISCO 4220 Flow Meter (Discontinued)
Pre-treatment compliance
Stormwater runoff monitoring
Permit enforcement
Sewer flow monitoring
Combined sewer overflow studies
Wastewater treatment plant operations
Inflow and infiltration studies
River and stream gauging
Size (H x W x D) | 17.0 x 11.5 x 10.5 in. (43 x 29 x 26.7 cm) (without power source) |
Weight | 17.3 lbs (7.8 kg) (without power source) |
Material | High-impact molded polystyrene structural foam |
Enclosure | NEMA 4X (iP65) |
Program Memory | Non-volatile, programmable flash. Updateable without opening enclosure. |
Display | Backlit LCD, 2-line, 80-character (5.5 mm high x 3.2 mm wide) |
Storage Temperature | -40° to 140°F (-40° to 60°C) |
Operating Temperature | 0° to 140°F (-18° to 60°C) |
Power | 12 to 14V DC, 24 mA average at 12.5V DC |
Typical Battery Life (printer set at 1 in/hr, 1 minute level reading interval) | |
934 NiCad Battery | 8 to 11 days |
946 Lead-Acid Battery | 12 to 16 days |
948 Lead-Acid Battery | 2 1/2 to 3 months |
Submerged Probe | |
Dimensions | 9.5 x 0.875 in (24.1 x 2.2 cm) |
Cable | Standard range probe - 25 ft x 0.3 in (7.6 m x 0.8 cm); |
Level Measurement Method | Submerged pressure transducer mounted in the flow stream |
Transducer Type | Differential linear integrated circuit pressure transducer |
Operating Temperature | 32° to 160°F (0° to 71°C) |
Submerged Probe (continued) | |
Compensated Temperature | 32° to 100°F (0° to 38°C) |
Level Measurement Range | 0.1 to 10 ft (0.03 to 3.05 m) |
Maximum Allowable Level | 20 ft (6.1 m) |
Col one | Col five |
Col one | Col five |
Level Measurement Accuracy (at 25°C (77°F) - Max error (±) for indicated level range) | |
0.1 to 5.0 ft (0.03 to 1.52 m) | ±0.01 ft (±0.003 m) |
0.1 to 7.0 ft (0.03 to 2.13 m) | ±0.03 ft (±0.009 m) |
0.1 to 10 ft (0.03 to 3.05 m) | ±0.10 ft (±0.03 m) |
Temperature Coefficient (Maximum error per degree of temperature change over compensated range) | |
0.1 to 4.0 ft (0.03 to1.22m) | ±0.005ft/°F (±0.0027m/°C) |
4.0 to 10 ft (1.22 to 3.05m) | ±0.007ft/°F (±0.0038m/°C) |
Materials | |
Submerged Probe | Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC |
Cable | Polyvinyl chloride (PVC) |