LTC Conductivity Datalogger - CTD Conductivity, Temperature, Depth

3001 LTC Levelogger Edge, M10 - C80 (Discontinued)

  • Conductivity, Temperature & Depth All in one with integral datalogger (16,000 data points)
  • Cost-effective CTD from Solinst 5-year battery life.
  • Salt water intrusion, groundwater monitoring, landfill leachate monitoring
  • Agricultural and stormwater runoff monitoring
Product Options
112696

Overview

PRODUCT DISCONTINUED - REPLACED BY THE LTC LEVELOGGER EDGE

The LTC Levelogger Junior conductivity datalogger (CTD) measures conductivity, temperature and depth all in one CTD device. It combines all three parameters within one conductivity data logger and has a 5 year battery life, memory capacity for 16,000 sets of readings in a small waterproof housing. Like the Levelogger Junior water level datalogger, it is very easy to program as well as being very small and easy to deploy in a range of environments and applications.

The LTC conductivity datalogger is totally compatible with Levelogger Software and all accessories as well is being able to be integrated into telemetry systems.

The 4-poll electrode platinum conductivity sensor has auto-ranging capabilities. The sealed conductivity data logger requires minimal maintenance and is simple to clean and calibrate, even in the field. Copper wire surrounds are also available to prevent algal/molusc growth around the sensor.

The Solinst CTD displays conductivity, temperature and temperature-compensated water level when using the standard Levelogger Software. The data logger can also record up to 16,000 sets of data readings. Measurements are linear and are taken at user defined intervals between 5 seconds and 99 hours.

Features

  • Low cost convenience
  • Conductivity, Level and Temperature data logging
  • Conductivity range 0-80,000µS/cm
  • 5 year battery life
  • 2% accuracy
  • Data storage for 16,000 data points
  • Real-time viewing and data export to other programs
  • SDI-12 compatible
  • Compatible with Levelogger Software, accessories, and STS Gold Telemetry Systems

Manufactured by: Solinst
Model: 3001 LTC Levelogger Edge, M10 - C80 (Discontinued)

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance

Applications

Salt water intrusion and soil salination monitoring
Plume remediation monitoring studies
Leachate monitoring at landfills, mine tailings, waste disposal storage sites and more
Agricultural and stormwater runoff monitoring
Tracer tests

Specification

Level Sensor: Piezoresistive Silicon with Hastelloy Sensor
Ranges F30/M10, F100/M3
Accuracy (typical) 0.1% FS
Resolution 0.08" (0.2 cm), 0.24" (0.6 cm)
Normalization Automatic Temp Compensation
Temperature Sensor: Platinum RTD
Accuracy ± 0.1°C
Resolution 0.1°C
Temp Compensation Range 10°C to 40°C
Conductivity Sensor: 4-Electrode Platinum
Full Range 0 - 80,000µS/cm
Accuracy 2% of reading or 20µS/cm
Resolution 1 µS
Temp. Compensation Range 0°C to 40°C
Normalization Specific Conductance @ 25°C
General:
Battery Life 5 Years (5 minute sampling rate)
Clock Accuracy ± 1 minute/year from 0 to 40°C
Operating Temperature - 20°C to 80°C
Memory Non-volatile EEPROM, FRAM back-up
Maximum Readings 16,000 sets of readings
Communication Optical Infra-red: USB, RS232, SDI-12
Size 7/8" x 7.5" (22 mm x 190 mm)
Weight 7.05 oz. (200 grams)
Wetted Materials Platinum, 316L Stainless Steel, Delrin® , Viton®
Sampling Mode Linear, (5 sec to 99 hrs), Real Time View
Barometric Compensation Software Wizard and Barologger Edge

Downloads

Accessories

Related products

FAQ's

The free app is available on both Apple® and Android™ smart devices.
Apple devices must be running iOS 11 or later on the following compatible devices:

  • iPhone
  • iPad
  • iPad mini
  • iPod touch.

Android devices must be running version 5.0 or higher. Solinst does not guarantee compatibility on all devices running 5.0, but testing confirms the following can be used:

  • Phone: Samsung Galaxy S4 - Model SGH-1337M
  • Phone: Samsung Galaxy S5 - Model SM-G900W8
  • Tablet: Samsung Tab 4 (10.1”) - Model SM-T530NU

As the Levelogger App Interface will not connect directly to the top of a Solinst datalogger, it is necessary to have connection accessories. With the Levelogger or Rainlogger, one of the following accessories is required:

  • Direct Read Cable, clients use this option to suspend dataloggers in the field when they wish to communicate downhole.
  • When working with Leveloggers that are suspended from wireline, or cord, the units must be removed from the well and connected to either a Direct Read Cable (as above) or an Optical Adaptor.
  • For the LevelVent, just connect to the unit via the Vented Cable and LevelVent Wellhead that all units are suspended from in the field – no other connection accessories are required.
  • The AquaVent communication connection is made from the App Interface to the AquaVent Wellhead using an App Connector Cable that is ordered separately.
The Levelogger App Interface is portable hardware that connects to the top of your Levelogger via a Direct Read Cable/Adaptor, to a LevelVent Wellhead, or to an AquaVent Wellhead cable. Bluetooth wireless technology allows communication between the Levelogger App Interface and the smart device with the app installed. It allows viewing/downloading of data, and programming of Solinst dataloggers, as well as many other features.
Solinst offers a wide range of dataloggers that can be used with the Leveloggger App Interface. They include the complete, current Levelogger Edge range of units (Edge, Junior Edge, LTC Edge, Rainlogger Edge), previous Gold Leveloggers/Barologgers, and the latest vented datalogger editions, the AquaVent and LevelVent.
  • Program and start dataloggers in the field.
  • Simplify data management in the field by transporting and using less equipment.
  • View real-time readings.
  • Download and e-mail logged data files.
  • Calibrate LTC Leveloggers (NEW).
  • Run the diagnostic utility (NEW) – used for troubleshooting

Leveloggers. Provides detailed information on the datalogger,
and includes options for running a self-test, doing a memory
dump and creating/emailing reports.